Setting object and carries no single field that identifies one alert lifecycle on its own. Flashduty requires the Template format instead: paste the JSON template below, and Catchpoint substitutes its macros with the values of the alert that triggered it.
In Flashduty On-call
Create either a dedicated or shared Catchpoint alert integration and copy its complete Push URL.
Configure Catchpoint
1
Create an Alert Webhook
- In the Catchpoint portal, open Integrations in the left navigation
- Find Webhook, then click Add URL → Alert Webhook
- Name it
Flashdutyand set the status to Active - Paste the complete Flashduty integration Push URL into Endpoint URL
2
Switch Format to Template and paste the JSON
Set Format to Template, click New Template, and paste the following JSON:
3
Assign the endpoint to your alerts
An Alert Webhook endpoint only receives pushes for alerts it is assigned to:
- Enable Apply to All Alerts on the endpoint to push every alert in the division/client to it, or
- Open the Alerts settings of a Test, Folder, Product, or RUM, and select the endpoint under API Endpoints
4
Verify the lifecycle
Let a test actually trigger a Warning or Critical alert, and confirm Flashduty receives an active alert. Then let the test recover, and confirm Flashduty receives the Improved notification and closes the original alert.
Alert Key
Flashduty derives the Alert Key from
test_id, alert_group_item_id, and alert_initial_trigger_epoch combined.
Catchpoint’s own PagerDuty Events API v2 integration template sets dedup_key to ${AlertInitialTriggerDateLocalEpoch} alone, and that single macro is enough to group the full Warning → Critical → Improved lifecycle into one PagerDuty incident. The macro index describes it as “The Alert-Initial-Trigger-Date-Local-Epoch timestamp, local time” — the local timestamp of when the alert first triggered, which stays the same for as long as that alert stays open. Flashduty adds test_id (the test ID) and alert_group_item_id (the alert rule item ID) on top, to reduce the chance of two different tests colliding on the same trigger second.
Changes to the title, description, severity, number of triggered nodes, or threshold never change the Alert Key.
Status and alert severity
Catchpoint’s
notification_level_id has 4 documented values:
A request with an empty or unsupported
notification_level_id is rejected. The Improved notification does not say which level the alert recovered from, so Flashduty shows it at Critical severity; the actual state is the recovery (Ok) status.
Troubleshooting
- Flashduty returns a parameter error: confirm Format is set to Template and the template is valid JSON; confirm
test_id,alert_group_item_id, andalert_initial_trigger_epochare still in the template and their macros were not removed or swapped for another macro - No alert is created: confirm the endpoint is selected under API Endpoints in the Alerts settings of the Test/Folder/Product, or that Apply to All Alerts is enabled on the endpoint
- The alert never recovers: the Improved notification goes through the same endpoint, no extra configuration is needed — confirm the test actually returned to a normal state rather than staying at Warning/Critical
- No deliveries show up at all: Catchpoint sends alerts from the Las Vegas datacenter range
64.147.163.0/24, over standard ports 443/80/8080 only; allow this range if a firewall or proxy sits in front of the push URL