Skip to main content
Use the webhook notification of a Pulsetic monitor to send down (monitor_offline), recovery (monitor_online) and SSL certificate expiring (certificate_expires_soon) notifications to Flashduty On-call. Each monitor maps to one Flashduty alert: the alert triggers when the monitor goes down and closes automatically when it recovers.

In Flashduty On-call


You can get the integration push URL in either of the following ways.

Use a dedicated integration

  1. In the Flashduty console, go to Channels and open a channel
  2. Select Configuration → Integrations → Private integration, then click Add an integration
  3. Select Pulsetic and click Save
  4. Open the new integration card and copy the push URL

Use a shared integration

  1. In the Flashduty console, go to Integration Center → Alert Events
  2. Select Pulsetic and enter an integration name
  3. Configure the default route and select a channel. You can add more rules under Routes after creation
  4. Click Save and copy the generated push URL

In Pulsetic


1

Open the monitor's webhook settings

  1. Log in to Pulsetic, go to Monitors, click ··· next to the monitor and select Alerts
  2. Under Developer Tools, select Webhook
  3. Paste the complete Flashduty push URL into Webhook URL and click Save
You can also configure it once under Account → Alerts so it applies to all monitors (General Alerts).
The free plan allows 1 webhook URL per monitor. Webhook notifications do not need a paid plan.
2

Send a test request (optional)

After saving, click Send test to show three buttons: Send Online Request, Send Offline Request and Send SSL Expires Soon Request. The Online and Offline buttons each create an Info alert titled Pulsetic test notification in Flashduty and do not affect the real alert of the monitor. The SSL button sends the real remaining days of the monitored address’s certificate, which cannot be told apart from a real reminder, so Flashduty handles it as one and creates a Warning alert. The test alert does not recover on its own, so close it manually after verifying.
3

Verify the lifecycle

Let a monitor go down for real (for example, point it to a URL that returns 5xx) and confirm Flashduty receives a Critical alert. Restore the target and confirm the alert closes.

Payload


Pulsetic POSTs the following fields as JSON. Flashduty parses them directly, with no template to configure: The alert title is the monitor name. When the name is empty, the monitored URL is used.

Alert Key


Flashduty uses monitor.id as the Alert Key for down and recovery alerts. The down, repeated down and recovery notifications of one monitor carry the same monitor.id, so they land on the same alert. Renaming the monitor or changing its URL or tags does not change the Alert Key. SSL certificate expiry notifications get their own Alert Key built from alert_type and monitor.id. Repeated reminders for one monitor merge into one alert, and they never close or update the down alert. When monitor.id is missing, Flashduty returns a parameter error because the recovery cannot be matched to the original alert.

Status and severity


Pulsetic notifications carry no severity. Flashduty maps them as follows: Any other alert_type (for example, a type Pulsetic adds later) is acknowledged and ignored without creating an alert.

FAQ


Pulsetic sends no recovery notification for certificate reminders. Turn on auto-close in the Flashduty integration or channel, with a suggested duration of 24 hours. A new reminder after the certificate is renewed triggers again.
The Online and Offline test buttons cannot. They send fixed sample values (for example the failure reason fail reason), so Flashduty recognises them and creates a separate Info alert, and never triggers, updates or closes the monitor’s real alert. The SSL test button creates a Warning alert (see above); close it manually after the check.
Pulsetic probes at the check interval set on the monitor, and you can set how long it waits after a failure before notifying under Intervals. Flashduty receives nothing until Pulsetic sends the notification.

Troubleshooting


  • Pulsetic does not push: confirm the monitor’s Alerts → Webhook is saved and the Webhook URL is the complete push URL including integration_key
  • Flashduty returns a parameter error: confirm the request body contains alert_type and monitor.id
  • An alert does not recover: confirm the recovery comes from the same monitor; monitor.id must match
For field details, see Pulsetic’s Webhook Notifications article.