down and up state changes to Flashduty On-call. Each monitoring job maps to one Flashduty alert. A job going down creates the alert, notify_repeat notifications merge into it, and the job coming back up recovers it.
In Flashduty On-call
Create either a dedicated or shared NS1 alert integration and copy its complete Push URL.
Configure NS1 Connect
1
Create a webhook notifier
Your account needs the Manage notifier lists permission.
- Sign in to NS1 Connect and go to Monitors → Notifier Lists
- Create a notifier list, or open an existing one, and click Add a new notifier
- Select Webhook as the Notifier type
- Paste the complete Flashduty integration Push URL into Webhook URL
- Click Create notifier and save the notifier in the list
2
Enable notifications on monitoring jobs
Open the monitoring job that should alert (new or existing) and select the notifier list in its notification settings.
3
Verify the lifecycle
Make the monitored endpoint genuinely unreachable and confirm Flashduty receives a Critical alert. Then restore the endpoint and confirm the same alert recovers. NS1 notifiers have no documented test button, so verify with a real state change.
Alert Key
Flashduty uses the monitoring job ID,
job_document.id, as the Alert Key. NS1’s official example of the down body carries the full job_document, whose id is the job ID. The down, repeated, and up notifications of one job share it.
If the job has job_document.notify_regional enabled, NS1 notifies per region. The Alert Key is then job_document.id/region, each region has its own alert, and one region recovering does not close another region’s alert. When it is off, the region is not part of the Alert Key, so a down and an up observed from different regions belong to the same alert.
Changes to the job name, the since timestamp, the region that observed the change, or the check configuration do not change the Alert Key.
NS1’s official documentation shows the full
down body only; its up example is truncated after since. Flashduty assumes the up body carries the same job_document. If an up body has no job_document.id, Flashduty rejects it instead of guessing which alert it belongs to.State and severity
NS1 sends no severity.
state is case-insensitive.
Labels
Flashduty keeps the labels
check (job name), resource (host, url, or domain from config), job_id, job_type, region, state, and notify_list for troubleshooting and routing on the alert page.
Troubleshooting
- The alert does not recover: confirm Notify failback is enabled on the monitoring job. If you cannot enable it, turn on auto-close timeout for the channel with a duration of 1 hour and the timer starting at incident trigger
- NS1 reports a webhook failure: confirm the Push URL is complete and includes
integration_key - Flashduty returns
job_document.id is required: the body has no monitoring job ID; check that the notification was sent by an NS1 monitoring job - Several alerts after enabling regional notifications: this is expected, each region is an independent alert