Skip to main content
Use Hyperping’s Webhooks integration to send monitor down (check.down) and recovery (check.up) notifications to Flashduty On-call. Each Hyperping monitor maps to one down alert: the alert triggers when the monitor goes down and recovers when the monitor is up again.

In Flashduty On-call


You can get the integration push URL in either of the following ways.

Use a dedicated integration

  1. In the Flashduty console, go to Channels and open a channel
  2. Select Configuration → Integrations → Private integration, then click Add an integration
  3. Select Hyperping and click Save
  4. Open the new integration card and copy the push URL

Use a shared integration

  1. In the Flashduty console, go to Integration Center → Alert Events
  2. Select Hyperping and enter an integration name
  3. Configure the default route and select a channel. You can add more rules under Routes after creation
  4. Click Save and copy the generated push URL

In Hyperping


1

Connect the Webhooks integration

  1. Sign in to Hyperping and open the Integrations page
  2. Click Connect on the Webhooks card
  3. Paste the full Flashduty push URL as the webhook URL and save
Webhooks are configured per project, not per monitor: once saved, down and recovery notifications for every monitor in the project go to this URL.
2

Verify the lifecycle

Hyperping recommends testing with a monitor that returns an error, such as a page that returns 404. Let a monitor actually go down and confirm Flashduty receives an active alert, then let it recover and confirm the same alert recovers.
The Webhook card on the Integrations page is marked Pro and needs the Pro plan or higher; during the free trial, clicking it redirects to the Billing page. If you cannot open the configuration, upgrade your plan first.

Payload


Hyperping POSTs JSON. Flashduty parses it directly, with no template to configure: The alert title is the monitored URL; when the URL is empty it is Hyperping monitor <monitor ID>.

Alert Key


The Alert Key is check.monitorUuid. In the Hyperping documentation, the check.down and check.up samples carry the same monitorUuid, so a monitor’s down and recovery notifications land on one alert, and different monitors produce different alerts. Changing the URL, status code, time, or check location does not change the Alert Key. If a request has no check.monitorUuid, Flashduty returns a parameter error, because the recovery could not be tied to its alert reliably. A notification whose event is neither check.down nor check.up (for example an event type Hyperping adds later) is ignored and acknowledged, and creates no alert.

Status and severity


Hyperping notifications carry no severity, so a down is treated as Critical. A request whose event is empty or any other value is rejected, so that a request of unknown state never enters the wrong alert lifecycle.

FAQ


Hyperping provides test buttons under the webhook URL field, and its documentation does not describe the test request body. If the test request carries event and check.monitorUuid, Flashduty handles it as a normal notification and creates an alert, which you close by hand. If those fields are missing, Flashduty returns a parameter error and Hyperping shows the delivery as failed; real notifications are not affected.
No. Notifications for the same monitor carry the same monitorUuid and merge into one alert.

Troubleshooting


  • Hyperping shows a failed delivery: confirm the webhook URL is the full push URL and includes integration_key
  • Flashduty returns a parameter error: confirm the request is a Hyperping JSON notification and that event and check.monitorUuid are not empty
  • The alert does not recover: confirm the recovery is sent to the same webhook; the recovery and the down notification must carry the same monitorUuid